Sierra Wireless AceView Guía de usuario Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 49
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
AirLink GX400 HSPA+ User Guide
22 2140712
Table 2-2: GX400 Digital I/O Specifications
Pin Name Specification Param Min Typ Max Units
4 Dig I/O
(Input)
Input low state
voltage
VIL -0.5 0 1.2 V
Input high state
voltage range
VIH 1.3 3.3 30 V
Input leakage current
(3.3 VDC IN)
IIN ---- 58 ---- μA
Typical application input source is a dry switch contact to ground.
Pin includes an internal 56K ohm pull up to 3.3 VDC.
Dig I/O
(Output)
Open drain drive to
ground
Idc ---- 150 200 mA
Maximum open
circuit voltage
applied
Voc ---- 3.3 30 V
Typical application is to drive a relay coil to ground.
Vista de pagina 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 48 49

Comentarios a estos manuales

Sin comentarios