Sierra Wireless AirLink MP Guía de usuario Pagina 114

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 237
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 113
ALEOS User Guide
108 20080616
Telnet Echo Mode Telnet Client Echo Mode.
n=0 : No Echo
n=1 : Local Echo (Default)
n=2 : Remote Echo
Enable ENQ on TCP
Connect
Outputs an ENQ [0x05] after the TCP CONNECT delayed by the Delay Connect Response
time (S221).
n=0 : Disabled (Default).
n=1 : Enable ENQ on CONNECT.
Command Description
Command Description
MD Default power-up mode for the serial port: When the MP device is power-cycled, the serial
port enters the mode specified by this command after 5 seconds. On startup, typing ATMD0
within 5 seconds changes the mode to normal (AT command) mode. See also S53 to set
the port for UDP .
hh (hex byte)=00 : normal
hh=01 : SLIP
hh=02 : PPP
hh=03 : UDP
hh=04 : TCP
hh=07 : PassThru
hh=0F : MP MDT
hh=13 : Modbus ASCII
hh=23 : Modbus RTU (Binary)
hh=33 : BSAP
hh=63 : Variable Modbus
hh=73 : Reliable UDP
hh=83 : UDP Multicast
UDP Auto Answer Enables UDP auto answer (half-open) mode.
n=0 : Normal mode
n=2 : Enable UDP auto answer mode.
UDP Idle Timeout Set or query UDP auto answer idle time-out. If no data is sent or received before the time-
out occurs, the current UDP session will be terminated. While a session is active, packets
from other IP addresses will be discarded (unless *UALL is set).
n=0 : No idle time-out (Default).
n=1 - 255 : Time-out in seconds.
UDP Connect Last If enabled, sets S53 to the last accepted IP address through UDP auto answer. This can be
used in conjunction with MD3 so that when there is no UDP session, new ethernet host
data will cause a connection to be restored to the last IP accepted through UDP auto
answer.
n=0 : Does not change S53 setting. (Default).
n=1 : Set S53 to the last accepted IP.