I/O Configuration
Rev 2.0 C Aug.10 121
Pulse Count
Following are some Pulse Count details:
• Pulses are counted on each of the digital inputs.
• Pulse counts 1-4 corresponds to digital 1-4 respectively.
• Pulses are counted on the falling edge.
• Pulses can not be counted when the device is powered off, or being reset.
However, a single state change while off or reset will be properly counted.
Transformed Analog
The number for the available transformed needs to indicate a variable based on
the number of Analog.
The analog input value is transformed into a meaningful value, such as weight or
pressure, by multiplying the raw value from the input by the coefficient and adding
the offset.
• Coefficient for Analog 1-4 - The amount by which the raw analog value
should be multiplied.
• Offset for Analog 1-4 - The offset to be added to the product of the coeffi-
cient and the raw analog value.
• Transformed Analog 1-4 - The value of the raw analog value multiplied by
the coefficient and then added to the offset.
• Units for Analog 1-4 - The name of the unit of measurement to be used in
reports.
Command Description
Relay # Initial Setting When the AirLink device reboots, the relay settings you want can be configured here.
Relay setting can be:
• ON
• OFF
• Last Value
Coefficient for
Analog #
Coefficient is the multiplier for raw analogs (*ANALOGIN).
Offset for Analog # Point at which Transformed Analog starts its count.
Units for Analog # This is the label for the Analog measurement. For example, litres or mm etc.