ALEOS User Guide
110 20080616
device PPP IP The IP for the AirLink device when comming through RS232.
Host PPP IP The IP for the Host RS232 Interface.
Command Description
Command Description
Passthrough Init
String
Any AT Command string to be passed to the OEM module before entering PASSTHRU
mode, e.g. AT&S1V1, etc.
• string=AT command(s)
Passthrough Init
Refresh (Minutes)
Number of minutes of inactivity in PASSTHRU mode to resend the *PTINIT string to the
hardware module.
• n=0 : Disabled
• n=1-255 minutes
device Reset Period
(Hours)
In PASSTHRU mode, device will be reset after this period if no data has been sent or
received. Value is in hours.
• n=0 : Disabled
• n=1-255 hours
Passthrough Echo PassThru Echo : Echo data to the host.
• n=0 : Data will be passed to the host.
• n=1 : PASSTHRU mode will echo all host received data and will not pass the data to
the device while the device is not asserting DCD.
Note: If the device is asserting DCD, data will be passed from the host to the device as it
normally is when *CSX1=0.
Disable AT Escape AT Escape Sequence detection.
• n=0 : Enable
• n=1 : Disable
Command Description
Variable Type The data-type of the RTU ID in a modbus-variant protocol. This parameter is used to define
the data-type of the RTU ID in Modbus-like protocol data packets. This parameter is used
when the Mode Default (MD) is set to 63.
Variable Offset Indicates the offset in the data of where the Modbus ID starts.
Variable Length Length of the RTU ID in a modbus-variant protocol, in bytes. This parameter is used to
define the length of the RTU ID in Modbus-like protocol data packets. This parameter is
used when the when the Mode Default (MD) is set to hex 63