ALEOS User Guide
208 20080616
S51 PAD data forwarding character. ASCII code of character that will cause data
to be forwarded. Used in UDP or TCP PAD mode.
• n=0 : No forwarding character.
E Toggle AT command echo mode.
• n=0 : Echo Off.
• n=1 : Echo On.
With more than one connection types (serial, and Telnet, and USB) the echo
command can be set differently on each interface.
&S Set DSR mode.
• n=0 : Always assert DSR (Default).
• n=1 : Assert DSR when in a data mode (UDP, TCP, PPP, or SLIP)
(Default).
• n=2 : Assert DSR when the device has network coverage.
S211 can also be used to request that DSR is always asserted. If S211 is set
to 3 and &S is changed to a non-zero value, S211 will be changed to 1.
&C Assert DCD
CTSE Clear To Send Enable: This feature asserts CTS when there is a network
connection.
• n=0 : Disabled (Default).
• n=1 : Enable assertion of CTS when there is network coverage.
RS232 voltage levels:
•
Positive = Network coverage.
•
Negative = No coverage.
Flow control (AT\Q) will override this indication, so if you want to use CTS to
indicate network coverage, flow control has to be off (AT\Q0).
X
Extended Call Progress Result mode.
•n=0 : Turn off extended result codes (Default).
•n=1 : Turn on result codes. This adds the text 19200 to the
CONNECT response.
*NUMTIOP
Convert 12 digit number to IP.
•n=0 : Use as name.
•n=1 : Use as IP address.
Table 6-8: Common: Serial
Command Description